Boiler control with domestic hot water control using a 3-port motorized valve
The following adjustments must be made before power is applied to the system:
1. System selection switches.
2. Burner cycles per hour (3 to 9), typical setting: 6.3.
3. Domestic hot water (35 to 100°C), typical setting: 55°C.
Note: The switch A–B should be in position A for the domestic hot water to be off when the system is controlling at the Economy level. The switch should be in position B for the domestic hot water to be continuously serviced. Wiring shows a priority valve. Where a mid-position valve is used the White (or Brown) and Grey go to terminal C.
I HAVE THIS SYSTEM IT IS VERY GOOD MY BOILER CYCLES WERE AT 3 I HAVE PUT IT TO 6 SEE HOW IT GOES I HAVE 2 MV S AND 2 PUMPS
WHERE CAN I GET ANY SPARES FOR THIS EVERYTHING IS OK ATHE MO