A.O. Smith 110-310-510 – CLEANING THE COMBUSTION COMPONENTS

Posted on January 19, 2022January 19, 2022

Procedure for cleaning the fan, burner, Flame Sensor and AFR, as used by all Service Representatives. 1)TOOLS ? Gather the following materials together: a. Degreaser…

Non-Condensing Models

A.O. Smith 110-310-510 – CLEANING THE ROD ASSEMBLY

Posted on January 19, 2022

1)TOOLS ? Gather the following materials together: a. Sheet of 100 Grit Sandpaper b. #2 Philips Screw Driver c. Flashlight 2)POWER ? Disconnect power to…

Non-Condensing Models

A.O. Smith 110-310-510 – CHECKING THE OVERHEAT CUTOFF FUSE (OHCF):

Posted on January 19, 2022

1) Locate the white OHCF which wraps around the heat exchanger. 2) Find the white clip at the end of the two blue braided wires…

Non-Condensing Models

A.O. Smith 110-310-510 – RESETTING THE COMPUTER BOARD:

Posted on January 19, 2022

1) Verify that there is no water flowing through the unit. 2) If a temperature remote controller has been installed, turn the power off to…

Non-Condensing Models

A.O. Smith 110-310-510 – ADJUSTING MANIFOLD PRESSURE

Posted on December 9, 2021

The manifold gas pressure of the tankless unit can be adjusted by the following procedure. 1) Set up the manometer by following steps 1 through…

Non-Condensing Models

A.O. Smith 110-310-510 – CHECKING MANIFOLD GAS PRESSURE

Posted on December 7, 2021

1) Ensure the unit is not in operation. 2) Remove the screw off the manifold port. 3) Connect a manometer to the manifold port using…

Non-Condensing Models

A.O. Smith 110-310-510 – PURGE THE GAS LINE OF AIR

Posted on December 7, 2021

1) The unit should not be running during this procedure. Turn off power to the unit. 2) Turn the gas valve to the off position…

Non-Condensing Models

A.O. Smith 110-310-510 – CHECK GAS SUPPLY PRESSURE

Posted on December 6, 2021December 7, 2021

1) Close the manual gas inlet shut off valve on the gas supply line. 2) Open a faucet. The unit should turn on and the…

Non-Condensing Models

A.O. Smith 110-310-510 – CHECKING FOR A CROSS CONNECTION

Posted on December 6, 2021

1) Turn off cold water supply. 2) Turn on all hot water fixtures. a. The water should eventually completely drain. b. If water continues to…

Non-Condensing Models

A.O. Smith 110-310-510 – CLEANING THE FILTER:

Posted on December 6, 2021December 6, 2021

1) Drain the unit (procedure above). 2) Check the water filter located within the cold inlet. With a tiny brush, clean the water filter of…

Posts navigation

Page 1 Page 2 … Page 4 Next Page

Pages

  • Contact Us

Recent Posts

  • A.O. Smith 110-310-510 – CLEANING THE COMBUSTION COMPONENTS
  • A.O. Smith 110-310-510 – CLEANING THE ROD ASSEMBLY
  • A.O. Smith 110-310-510 – CHECKING THE OVERHEAT CUTOFF FUSE (OHCF):
  • A.O. Smith 110-310-510 – RESETTING THE COMPUTER BOARD:
  • A.O. Smith 110-310-510 – ADJUSTING MANIFOLD PRESSURE

Categories

  • Bradford White RG150T6N
  • Coal Firing
  • Gas and Oil Controls
  • Gas Burners
  • Honeywell Thermostat Manuals
  • Non-Condensing Models
  • Oil Burner
  • Steam and Hydronic Line
  • Thermostats and Humidistats
  • Valve
  • Wiring and Controls
© Copyright 2023 – Heater Service & Troubleshooting
Wisteria Theme by WPFriendship ⋅ Powered by WordPress

Terms and Conditions - Privacy Policy